PSE – Soft Starters 22KW-110KW

Description: Softstarter, Rated Operationanl Voltage: 208-600VAC, Rated Operational Power-In-Line: 110KW, Rated Operational Current-In-Line Connection: 210A, 50/60Hz, Adjustable Rated Motor Current: 30-100%, Analog Outputs: 4-20mA, By-pass Signal Relay: Yes, Fault-Signal Relay: Yes, Initial Voltage During Start: 30-70%, Number of Starts per Hour at 3.5*Ie for 7 sec. 50%ON Time 50%OFF Time: 10, Overload Signal Relay: Yes, Rated Control Circuit Voltage: DC Operation 24V, Rated Control Supply Voltage: 100-250VAC, Run Signal Relay: Yes, Service Factor Percentage: 100%, Step Down Voltage Special Ramp: No.
SKU: PSE210-600-70 / 1SFA897112R7000 Categories: ,
Brand: ABB
  • SKU: PSE45-600-70 / 1SFA897105R7000
    Softstarter, Rated Operationanl Voltage: 208-600VAC, Rated Operational Power-In-Line: 22KW, Rated Operational Current-In-Line Connection: 45A, 50/60Hz, Adjustable Rated Motor Current: 30-100%, Analog Outputs: 4-20mA, By-pass Signal Relay: Yes, Fault-Signal Relay: Yes, Initial Voltage During Start: 30-70%, Number of Starts per Hour at 3.5*Ie for 7 sec. 50%ON Time 50%OFF Time: 10, Overload Signal Relay: Yes, Rated Control Circuit Voltage: DC Operation 24V, Rated Control Supply Voltage: 100-250VAC, Run Signal Relay: Yes, Service Factor Percentage: 100%, Step Down Voltage Special Ramp: No. 
  • SKU: PSE60-600-70 / 1SFA897106R7000
    Softstarter, Rated Operationanl Voltage: 208-600VAC, Rated Operational Power-In-Line: 30KW, Rated Operational Current-In-Line Connection: 143A, 50/60Hz, Adjustable Rated Motor Current: 30-100%, Analog Outputs: 4-20mA, By-pass Signal Relay: Yes, Fault-Signal Relay: Yes, Initial Voltage During Start: 30-70%, Number of Starts per Hour at 3.5*Ie for 7 sec. 50%ON Time 50%OFF Time: 10, Overload Signal Relay: Yes, Rated Control Circuit Voltage: DC Operation 24V, Rated Control Supply Voltage: 100-250VAC, Run Signal Relay: Yes, Service Factor Percentage: 100%, Step Down Voltage Special Ramp: No. 
  • SKU: PSE142-600-70 / 1SFA897110R7000
    Softstarter, Rated Operationanl Voltage: 208-600VAC, Rated Operational Power-In-Line: 75KW, Rated Operational Current-In-Line Connection: 143A, 50/60Hz, Adjustable Rated Motor Current: 30-100%, Analog Outputs: 4-20mA, By-pass Signal Relay: Yes, Fault-Signal Relay: Yes, Initial Voltage During Start: 30-70%, Number of Starts per Hour at 3.5*Ie for 7 sec. 50%ON Time 50%OFF Time: 10, Overload Signal Relay: Yes, Rated Control Circuit Voltage: DC Operation 24V, Rated Control Supply Voltage: 100-250VAC, Run Signal Relay: Yes, Service Factor Percentage: 100%, Step Down Voltage Special Ramp: No.
  • SKU: PSE370-600-70 / 1SFA897115R7000
    Softstarter, Rated Operationanl Voltage: 208-600VAC, Rated Operational Power-In-Line: 110KW, Rated Operational Current-In-Line Connection: 370A, 50/60Hz, Adjustable Rated Motor Current: 30-115%, Analog Outputs: 4-20mA, By-pass Signal Relay: Yes, Fault-Signal Relay: Yes, Initial Voltage During Start: 30-70%, Number of Starts per Hour at 3.5*Ie for 7 sec. 50%ON Time 50%OFF Time: 10, Overload Signal Relay: Yes, Rated Control Circuit Voltage: DC Operation 24V, Rated Control Supply Voltage: 100-250VAC, Run Signal Relay: Yes, Service Factor Percentage: 100%, Step Down Voltage Special Ramp: No.