DSC_8791 (FILEminimizer)

Share

GV2P/GV3P Thermal Magnetic Circuit Breaker – Rotary knob

Description: TeSys GV2 - Motor Circuit Breaker, Thermal-magnetic, 0.12-0.18kW at 400-415VAC, Breaking capacity 100kA at 400-415VAC, Trip unit rating 0.40-0.63A, Magnetic Tripping current 8A, 3 Poles, control-type: Rotary knob, IP20
SKU: GV2P04 Categories: ,
  • SKU: GV2P01
    TeSys GV2 – Motor Circuit Breaker, Thermal-magnetic, Breaking capacity 100kA at 400-415VAC, Trip unit rating 0.1-0.16A, Magnetic Tripping current 1.5A, 3 Poles, control-type: Rotary knob, IP20.
  • SKU: GV2P03
    TeSys GV2 – Motor Circuit Breaker, Thermal-magnetic, 0.09kW at 400-415VAC, Breaking capacity 100kA at 400-415VAC, Trip unit rating 0.25-0.40A, Magnetic Tripping current 5A, 3 Poles, control-type: Rotary knob, IP20.
  • SKU: GV2P05
    TeSys GV2 – Motor Circuit Breaker, Thermal-magnetic, 0.25kW at 400-415VAC, Breaking capacity 100kA at 400-415VAC, Trip unit rating 0.63-1.0A, Magnetic Tripping current 13A, 3 Poles, control-type: Rotary knob, IP20.
  • SKU: GV2P06
    TeSys GV2 – Motor Circuit Breaker, Thermal-magnetic, 0.37-0.55kW at 400-415VAC, Breaking capacity 100kA at 400-415VAC, Trip unit rating 1.0-1.6A, Magnetic Tripping current 22.5A, 3 Poles, control-type: Rotary knob, IP20.
  • SKU: GV2P07
    TeSys GV2 – Motor Circuit Breaker, Thermal-magnetic, 0.75kW at 400-415VAC, Breaking capacity 100kA at 400-415VAC, Trip unit rating 1.6-2.5A, Magnetic Tripping current 33.5A, 3 Poles, control-type: Rotary knob, IP20.
  • SKU: GV2P08
    TeSys GV2 – Motor Circuit Breaker, Thermal-magnetic, 1.1kW at 400-415VAC, Breaking capacity 100kA at 400-415VAC, Trip unit rating 2.5-4.0A, Magnetic Tripping current 51A, 3 Poles, control-type: Rotary knob, IP20.
  • SKU: GV2P10
    TeSys GV2 – Motor Circuit Breaker, Thermal-magnetic, 2.2kW at 400-415VAC, Breaking capacity 100kA at 400-415VAC, Trip unit rating 4.0-6.3A, Magnetic Tripping current 78A, 3 Poles, control-type: Rotary knob, IP20.
  • SKU: GV2P14
    TeSys GV2 – Motor Circuit Breaker, Thermal-magnetic, 3kW at 400-415VAC, Breaking capacity 100kA at 400-415VAC, Trip unit rating 6-10A, Magnetic Tripping current 138A, 3 Poles, control-type: Rotary knob, IP20.
  • SKU: GV2P16
    TeSys GV2 – Motor Circuit Breaker, Thermal-magnetic, 5.5kW at 400-415VAC, Breaking capacity 100kA at 400-415VAC, Trip unit rating 9-14A, Magnetic Tripping current 170A, 3 Poles, control-type: Rotary knob, IP20.
  • SKU: GV2P20
    TeSys GV2 – Motor Circuit Breaker, Thermal-magnetic, 7.5kW at 400-415VAC, Breaking capacity 50kA at 400-415VAC, Trip unit rating 13-18A, Magnetic Tripping current 223A, 3 Poles, control-type: Rotary knob, IP20.
  • SKU: GV2P21
    TeSys GV2 – Motor Circuit Breaker, Thermal-magnetic, 9kW at 400-415VAC, Breaking capacity 50kA at 400-415VAC, Trip unit rating 17-23A, Magnetic Tripping current 327A, 3 Poles, control-type: Rotary knob, IP20.
  • SKU: GV2P22
    TeSys GV2 – Motor Circuit Breaker, Thermal-magnetic, 11kW at 400-415VAC, Breaking capacity 50kA at 400-415VAC, Trip unit rating 20-25A, Magnetic Tripping current 327A, 3 Poles, control-type: Rotary knob, IP20.
  • SKU: GV2P32
    TeSys GV2 – Motor Circuit Breaker, Thermal-magnetic, 15kW at 400-415VAC, Breaking capacity 35kA at 400-415VAC, Trip unit rating 24-32A, Magnetic Tripping current 416A, 3 Poles, control-type: Rotary knob, IP20.
  • SKU: GV3P18
    TeSys GV3 – Motor Circuit breaker, Thermal-magnetic, 7.5kW at 400-415VAC, Breaking capacity 100kA at 400-415VAC, Trip unit current 12-18A, Magnetic Tripping current 252A, 3 Poles, control-type: Rotary knob, IP20.
  • SKU: GV3P25
    TeSys GV3 – Motor Circuit breaker, Thermal-magnetic, 11kW at 400-415VAC, Breaking capacity 100kA at 400-415VAC, Trip unit current 17-25A, Magnetic Tripping current 350A, 3 Poles, control-type: Rotary knob, IP20.
  • SKU: GV3P32
    TeSys GV3 – Motor Circuit breaker, Thermal-magnetic, 15kW at 400-415VAC, Breaking capacity 100kA at 400-415VAC, Trip unit current 23-32A, Magnetic Tripping current 448A, 3 Poles, control-type: Rotary knob, IP20.
  • SKU: GV3P40
    TeSys GV3 – Motor Circuit breaker, Thermal-magnetic, 18.5kW at 400-415VAC, Breaking capacity 50kA at 400-415VAC, Trip unit current 30-40A, Magnetic Tripping current 560A, 3 Poles, control-type: Rotary knob, IP20.
  • SKU: GV3P50
    TeSys GV3 – Motor Circuit breaker, Thermal-magnetic, 22kW at 400-415VAC, Breaking capacity 50kA at 400-415VAC, Trip unit current 37-50A, Magnetic Tripping current 700A, 3 Poles, control-type: Rotary knob, IP20.
  • SKU: GV3P65
    TeSys GV3 – Motor Circuit breaker, Thermal-magnetic, 30kW at 400-415VAC, Breaking capacity 50kA at 400-415VAC, Trip unit current 48-65A, Magnetic Tripping current 910A, 3 Poles, control-type: Rotary knob, IP20.
  • SKU: GV3P73
    TeSys GV3 – Motor Circuit breaker, Thermal-magnetic, 37kW at 400-415VAC, Breaking capacity 50kA at 400-415VAC, Trip unit current 62-73A, Magnetic Tripping current 1120A, 3 Poles, control-type: Rotary knob, IP20.
  • SKU: GV3P80
    TeSys GV3 – Motor Circuit breaker, Thermal-magnetic, 45kW at 400-415VAC, Breaking capacity 50kA at 400-415VAC, Trip unit current 70-80A, Magnetic Tripping current 1120, 3 Poles, control-type: Rotary knob, IP20.